Technical Specifications

6.  TECHNICAL SPECIFICATIONS

 

    6.1. Space area - gross:

         6.1.1. Pavilion 1 5250 sq m usable area: W 42m x L 125m

         6.1.2. Pavilion 2 - 1460 sq m

         6.1.3. Pavilion 3 3600 sq m usable area: W 48m x L 75m

    6.2. Height of the premises:

         6.2.1. Pavilion 1  - total 10m, usable 8m

         6.2.2. Pavilion 2  - total 4m, usable 3.7m

         6.2.3. Pavilion 3  - total 10m, usable 8m

         6.2.4. Garage under pavilion 1 – 2.2m

    6.3. Dimensions of goods gates:

         6.3.1. Height – 4.3m

         6.3.2. Width  - 4.6m

    6.4. Goods lift in hall 1 to the storage area in the basement and pavilion level:
           Door dimensions: Width – 2.0m, Height – 2.1m
           Lift dimensions: Width – 2.7m, Depth – 3.6m, Height – 2.3m
           Loading capacity - 3000kg

    6.5. Passenger lift in pavilion 2 to the underground car park:
           Dimensions : Width – 1.1m,  Depth – 2.3m,  Height – 2.0m

    6.6. Floor load:

          6.6.1. Pavilion 1 - 800 kg/sq m

          6.6.2. Pavilion 2 - 500 kg/sq m

          6.6.3. Pavilion 3 - 3000 kg/sq m

    6.7. Pavilions 1 and 3 have a ducting system with media networks: electrical

           installation, water and sewage installation, telephone and internet 

           installation. 
           In pavilion 2 connections to installation are located in the recessed  on the

           walls round the hall.

    6.8. Electrical installation characteristics:

          6.8.1. 5 conductor cable installation

          6.8.2. shock prevention by variable current switches

          6.8.3. connection to EXPO XXI power network after installation completed

                    according to the electrical drawing terminated in electrical boxes

          6.8.4. allocated 24 hrs circuits 230 V

    6.9. Water inflow and outflow connection:

          6.9.1. inflow diameter   - 15 mm

          6.9.2. outflow diameter - 50 mm

    6.10. All exhibition and conference rooms are equipped with fire alarms (smoke

             and temperature detectors)